- News
- Books
Featured Books
- design007 Magazine
Latest Issues
Current IssueLevel Up Your Design Skills
This month, our contributors discuss the PCB design classes available at IPC APEX EXPO 2024. As they explain, these courses cover everything from the basics of design through avoiding over-constraining high-speed boards, and so much more!
Opportunities and Challenges
In this issue, our expert contributors discuss the many opportunities and challenges in the PCB design community, and what can be done to grow the numbers of PCB designers—and design instructors.
Embedded Design Techniques
Our expert contributors provide the knowledge this month that designers need to be aware of to make intelligent, educated decisions about embedded design. Many design and manufacturing hurdles can trip up designers who are new to this technology.
- Articles
- Columns
Search Console
- Links
- Events
||| MENU - design007 Magazine
Estimated reading time: 1 minute
Beat the Traffic Jam - Effective Routing of Multiple Loads
In a previous Beyond Design, Impedance Matching: Terminations, I discussed various termination strategies and concluded that a series terminator is best for high-speed transmission lines. Different terminating strategies have advantages and disadvantages depending on the application, but, in general, series termination is excellent for point-to-point routes, one load per net. In summary, series termination reduces ringing and ground bounce.
But, what if there are a number of loads--how should these transmission lines be routed? For perfect transfer of energy and to eliminate reflections, the impedance of the source must equal the impedance of the trace(s) to the load.
Bifurcated transmission lines, traces that are split into two or more T-sections, are sometimes used to distribute signals to multiple loads. The impedance of the bifurcated line is not constant along the trace route, as the traces branching from the T-section are virtually in parallel when you consider the equivalent AC circuit. In this case, proper termination has not been provided and an impedance discontinuity can be seen at the branch point. In Figure 1, a 50 ohm signal from the driver is split into two transmission lines of 50 ohms and then into the loads. At branch (A), the two 50 ohm traces in parallel equate to a 25 ohm equivalent trace, and a mismatch in impedance. Figure 2 illustrates the resultant waveform of the unmatched transmission line.
Editor's Note: This column originally appeared in the February 2014 issue of The PCB Design Magazine.
More Columns from Beyond Design
Beyond Design: The Art of Presenting PCB Design CoursesBeyond Design: Embedded Capacitance Material
Beyond Design: Return Path Optimization
Beyond Design: Just a Matter of Time
Beyond Design: Design Success with IPC Standards
Beyond Design: Integrating AI Into PCB Design Flow
Beyond Design: Standing Waves in Multilayer PCB Plane Cavities
Beyond Design: Balancing Trade-offs for Optimal PCB Design